Comparison Matrix

Explore the differences and similarities between various options or choices with the help of a Comparison Matrix, allowing you to make more informed decisions based on a comprehensive analysis.

 

 

 

           
  BITE2 vs Alber,BITE2 vs Fluke   BITE2 vs Midtronics,BITE5 vs Alber   BITE2 vs HIOKI,BITE5 vs Midtronics


 

 

 

 

 

 

           
  BITE5 vs HIOKI   BITE5 vs Fluke   BITE5 ADVANCED vsAlber


 

 

 

BITE5 ADVANCED vsMidtronics                   BITE5 ADVANCED vs HIOKI                  BITE5 ADVANCEDvs Fluke


 

 

Brand

Megger

 

Alber

 

BITE2 Advantages

Both the BITE2 and the Alber test with high current. They can both be used to test large, flooded lead acid cells. However, the Alber unit draws the high current from the cells, the BITE2 does not. This means that the Alber discharges the cell during a test. Therefore, you cannot repeat a measurement until the battery has recharged.

This means if you make a mistake during testing you must wait for the string to recharge before you can re-take any measurements.

 

If you wish to test inter-cell connections with the Alber, then you must use a complicated 3 probe connection routine. It is easy to make a mistake using this method. The other option eliminates the 3 leads but requires 2 passes through the string, greatly increasing test time.

The Alber cannot be used on NiCD batteries unless special spade leads are used. Since NiCD battery posts are not normally accessible, the measurements need to be made on the hardware. Since the Alber unit draws high current from the cells, it creates a large voltage drop across the hardware. This means you measure the resistance of the hardware, not the battery. The spade adapters try to allow the user to slide under the hardware. This is difficult and not always possible. Since the BITE2 injects current through the entire string this is not an issue. The test current does not go through the hardware, so it can measure NiCD batteries.

 

Model

BITE2/2P

 

CRT-400

Cellcorder

 

Picture

 

 

 

 

Cell Voltage

˜

 

˜

 

Cell Resistance

 

 

˜

 

Cell Impedance

˜

 

 

 

Cell Conductance

 

 

 

 

Strap Resistance

˜

 

˜

 

Ripple Current

˜

 

 

 

DC Float Current

 

 

 

 

Escape Current

 

 

 

 

Temperature

 

 

 

 

Capacity Testing DC

Measurements

 

 

 

 

Measures DC Voltage

 

 

 

 

Measures AC Voltage

 

 

 

 

Kelvin Clips

 

 

˜

 

Single Tip Probes

˜

 

˜

 

Duplex Probes

 

 

 

 

Concentric Probes

 

 

 

 

Probe Extenders

˜

 

˜

 

Display

LCD

 

LCD

 

Memory

2000 readings /

300 test

 

1 MB per 71

strings with 256 cells

 

Removable Memory

 

 

USB Stick

 

Printer

BITE2P Only

 

Optional

 

Power

100 to 130 V, 210

to 250 V, 50/60 Hz

 

4 cell - 8800 mAh

lithium ion

 

Dimensions (inches)

T 6.5 x 14 x 10.6

R 7.25 x 11.25 x 2

 

12 x 7 x 3

 

Weight (pounds)

T = 17 / R = 1.6

 

3.4

 

RS-232 Com Port

˜

 

 

 

USB Port

 

 

 

 

Bluetooth Port

 

 

Optional Earpiece

 

Auto Detect Cell-Strap

 

 

 

 

On Board Data

Analysis

 

 

 

 

Accuracy

1%

 

 

 

Max Voltage

25.0VDC

 

20.0VDC

 

Test Current

10A

 

35A

 

Temperature

Operating Range

0 to 40C

 

0 to 40C

 

Humidity @ 40C >=

90%

90%NC

 

50%NC


 

 

Brand

Megger

 

Midtronics

 

BITE2 Advantages

The BITE2 tests with high current, the Midtronics does not. The BITE2 can be used to test large, flooded lead acid cells, which have low impedance values. The Midtronics unit does not have the resolution to see the small changes.

Any inter-cell measurements made with the Midtronics unit will be relative. (Compared to previous measurements.) The BITE2 injects current through the entire string creating a uniform current density. This means the inter-cell measurements will be absolute.

 

The low-test current used by Midtronics makes this unit susceptible to string noise. This can cause fluctuations in measurements. The high-test current used by the BITE2 makes the BITE2 far less susceptible to noise.

 

The Midtronics unit cannot be used on NiCD batteries. NiCD battery posts are not normally accessible. Measurements are made on the hardware. The Midtronics will inject current through the hardware. This creates a voltage drop across the hardware. This means you measure the resistance of the hardware, not the battery. The BITE2 injects current through the entire string. The test current does not go

through the hardware, so it can measure NiCD batteries.

 

Model

BITE2/2P

 

Celltron Advantage

 

Picture

 

 

 

 

Cell Voltage

˜

 

˜

 

Cell Resistance

 

 

 

 

Cell Impedance

˜

 

 

 

Cell Conductance

 

 

˜

 

Strap Resistance

˜

 

˜

 

Ripple Current

˜

 

 

 

DC Float Current

 

 

 

 

Escape Current

 

 

 

 

Temperature

 

 

˜

 

Capacity Testing DC

Measurements

 

 

 

 

Measures DC Voltage

 

 

 

 

Measures AC Voltage

 

 

 

 

Kelvin Clips

 

 

˜

 

Single Tip Probes

˜

 

 

 

Duplex Probes

 

 

˜

 

Concentric Probes

 

 

 

 

Probe Extenders

˜

 

˜

 

Display

LCD

 

LCD

 

Memory

2000 readings /

300 test

 

14000 test

 

Removable Memory

 

 

˜

 

Printer

BITE2P Only

 

Protocol for Printer

 

Power

100 to 130 V, 210

to 250 V, 50/60 Hz

 

7.2V, 2500mAh,

NiMH rechargable

 

Dimensions (inches)

T 6.5 x 14 x 10.6

R 7.25 x 11.25 x 2

 

11 x 4 x 3

 

Weight (pounds)

T = 17 / R = 1.6

 

2.6

 

RS-232 Com Port

˜

 

 

 

USB Port

 

 

˜

 

Bluetooth Port

 

 

 

 

Auto Detect Cell-Strap

 

 

 

 

On Board Data Analysis

 

 

˜

 

Accuracy

1%

 

2%

 

Max Voltage

25.0VDC

 

20.0VDC

 

Test Current

10A

 

200mA

 

Temperature Operating

Range

0 to 40C

 

0 to 40C

 

Humidity @ 40C >= 90%

90%NC

 

95%NC


 

 

Brand

Megger

 

HIOKI

 

BITE2 Advantages

The BITE2 tests with high current, the HIOKI does not. The BITE2 can be used to test large, flooded lead acid cells, which have low impedance values. The HIOKI unit does not have the resolution to see small changes in these large cells.

The HIOKI does not measure inter- cell (strap) resistance. The BITE2 does. NOTE: This is required for any NERC compliant testing.

 

The low-test current used by HIOKI makes this unit susceptible to string noise. The low signal to noise ratio, can cause fluctuations in the cell measurement. The high-test current used by the BITE2 makes the BITE2 far less susceptible to noise.

The HIOKI unit cannot be used on NiCD batteries. Since NiCD battery posts are not normally accessible, the measurements are made on the hardware. The HIOKI will inject current through the hardware. This creates a voltage drop across the hardware. This means you measure the resistance of the hardware, not the battery. The BITE2 injects current through the entire string.

The test current does not go through the hardware, so it can measure NiCD batteries.

 

 

 

 

 

 

 

 

Model

BITE2/2P

 

3554

 

Picture

 

 

 

 

Cell Voltage

˜

 

˜

 

Cell Resistance

 

 

 

 

Cell Impedance

˜

 

˜

 

Cell Conductance

 

 

 

 

Strap Resistance

˜

 

 

 

Ripple Current

˜

 

 

 

DC Float Current

 

 

 

 

Escape Current

 

 

 

 

Temperature

 

 

˜

 

Capacity Testing DC

Measurements

 

 

 

 

Measures DC Voltage

 

 

 

 

Measures AC Voltage

 

 

 

 

Kelvin Clips

 

 

 

 

Single Tip Probes

˜

 

 

 

Duplex Probes

 

 

˜

 

Concentric Probes

 

 

˜

 

Probe Extenders

˜

 

 

 

Display

LCD

 

LCD

 

Memory

2000 readings /

300 test

 

4800 sets

 

Removable Memory

 

 

 

 

Printer

BITE2P Only

 

 

 

Power

100 to 130 V, 210

to 250 V, 50/60 Hz

 

8 AA Alkaline

Batteries

 

Dimensions (inches)

T 6.5 x 14 x 10.6

R 7.25 x 11.25 x 2

 

7.6 x 4.8 x 2.2

 

Weight (pounds)

T = 17 / R = 1.6

 

1.75

 

RS-232 Com Port

˜

 

 

 

USB Port

 

 

˜

 

Bluetooth Port

 

 

 

 

Auto Detect Cell-Strap

 

 

 

 

On Board Data Analysis

 

 

 

 

Accuracy

1%

 

1%

 

Max Voltage

25.0VDC

 

60.0VDC

 

Test Current

10A

 

100mA

 

Temperature Operating

Range

0 to 40C

 

0 to 40C

 

Humidity @ 40C >= 90%

90%NC

 

80%NC


 

 

Brand

Megger

 

Fluke

Fluke

 

BITE2 Advantages

The BITE2 tests with high current, the Fluke does not. Fluke does not have resolution for large, flooded lead acid cells, which have low impedance values.

The Fluke BT510 does not measure inter-cell (strap) resistance. The BITE2 does. NOTE: This is required for any NERC compliant testing.

NOTE: The BT521 does measure straps but only with 100mA. This is insufficient current for a good reading.

 

The low-test current used by Fluke makes this unit susceptible to string noise.

 

The Fluke unit cannot be used on NiCD batteries. Since NiCD battery posts are not normally accessible, the measurements are made on the hardware. The Fluke will inject current through the hardware. This creates a voltage drop across the hardware. This means you measure the resistance of the hardware, not the battery. The BITE2 injects current through the entire string. The test current does not go through the hardware, so it can measure NiCD batteries.

 

 

 

 

Model

BITE2/2P

 

BT-510

BT-521

 

Picture

 

 

 

 

 

Cell Voltage

˜

 

˜

˜

 

Cell Resistance

 

 

 

 

 

Cell Impedance

˜

 

˜

˜

 

Cell Conductance

 

 

 

 

 

Strap Resistance

˜

 

 

˜

 

Ripple Current

˜

 

 

˜

 

DC Float Current

 

 

 

˜

 

Escape Current

 

 

 

 

 

Temperature

 

 

 

˜

 

Capacity Testing DC

Measurements

 

 

 

 

 

Measures DC Voltage

 

 

1000Vdc

1000Vdc

 

Measures AC Voltage

 

 

600Vac

600Vac

 

Kelvin Clips

 

 

 

 

 

Single Tip Probes

˜

 

 

 

 

Duplex Probes

 

 

˜

˜

 

Concentric Probes

 

 

˜

˜

 

Probe Extenders

˜

 

Optional

Optional

 

Display

LCD

 

LCD

LCD

 

Memory

2000 readings /

300 test

 

 

 

 

Removable Memory

 

 

 

 

 

Printer

BITE2P Only

 

 

 

 

Power

100 to 130 V,

210 to 250 V,

50/60 Hz

 

7.4V,3Ah,

Rechargeable Lithium

7.4V,3Ah,

Rechargeable Lithium

 

Dimensions (inches)

T 6.5 x 14 x

10.6

R 7.25 x 11.25 x

2

 

 

9.0 x 4.0 x 2.0

 

9.0 x 4.0 x 2.0

 

Weight (pounds)

T = 17 / R = 1.6

 

1.9

1.9

 

RS-232 Com Port

˜

 

 

 

 

USB Port

 

 

˜

˜

 

Bluetooth Port

 

 

 

˜

 

Auto Detect Cell-Strap

 

 

 

 

 

On Board Data Analysis

 

 

 

 

 

Accuracy

1%

 

1%

1%

 

Max Voltage

25.0VDC

 

60VDC

60VDC

 

Test Current

10A

 

100mA

100mA

 

Temperature Operating

Range

0 to 40C

 

0 to 40C

0 to 40C

 

Humidity @ 40C >= 90%

90%NC

 

80%NC

80%NC


 

 

Brand

Megger

Alber

BITE5 Advantages

The BITE5 can test battery packs up to 200Vdc - Alber cannot.

The BITE5 can test Lithium-Ion batteries - Alber cannot.

The BITE5 can measure battery temperature - Alber cannot.

The BITE5 offers concentric probes for batteries with terminal caps - Alber does not.

 

The BITE5 can measure DC float current - Alber cannot.

 

The BITE5 has a large color touchscreen display - Alber does not.

 

The BITE5 can trend historical data - Alber cannot.

The BITE5 can measure DC voltages up to 1000V - Alber cannot.

 

The BITE5 supports discharge testing - Alber does not.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

BITE5

 

CRT-400

Cellcorder

 

Picture

 

 

 

 

Cell Voltage

˜

 

˜

 

Cell Resistance

 

 

˜

 

Cell Impedance

˜

 

 

 

Cell Conductance

˜

 

 

 

Strap Resistance

 

 

˜

 

Ripple Current

˜

 

 

 

DC Float Current

˜

 

 

 

Escape Current

 

 

 

 

Temperature

˜

 

 

 

Capacity Testing DC

Measurements

˜

 

 

 

Measures DC Voltage

1000Vdc

 

 

 

Measures AC Voltage

600Vac

 

 

 

Kelvin Clips

˜

 

˜

 

Single Tip Probes

 

 

˜

 

Duplex Probes

˜

 

 

 

Concentric Probes

˜

 

 

 

Probe Extenders

˜

 

˜

 

Display

Touchscreen

 

LCD

 

Memory

 

16G

 

1 MB per 71

strings with 256 cells

 

Removable Memory

˜

 

USB Stick

 

Printer

 

 

Optional

 

Power

 

 

4 cell - 8800 mAh

lithium ion

 

Dimensions (inches)

240 x 160 x 65

 

12 x 7 x 3

 

Weight (pounds)

1.98

 

3.4

 

RS-232 Com Port

 

 

 

 

USB Port

˜

 

 

 

Bluetooth Port

 

 

Optional Earpiece

 

Auto Detect Cell-Strap

 

 

 

 

On Board Data Analysis

˜

 

 

 

Accuracy

1%

 

 

 

Max Voltage

200Vdc

 

20.0VDC

 

Test Current

100mA

 

35A

 

Temperature Operating

Range

0 to 50C

 

0 to 40C

 

Humidity @ 40C >= 90%

85%NC

 

50%NC


 

 

Brand

Megger

 

Midtronics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BITE5 Advantages

The BITE5 can test battery packs up to 200Vdc - Midtronics cannot.

The BITE5 can test Lithium-Ion batteries - Midtronics cannot.

The BITE5 can measure AC Ripple current - Midtronics cannot.

 

The BITE5 has a large color touchscreen display - Midtronics does not.

The BITE5 can measure DC float current - Midtronics cannot.

The BITE5 can trend historical data - Midtronics cannot.

 

The BITE5 supports discharge testing - Midtronics does not.

The BITE5 offers an optional hydrometer - Midtronics does not.

 

The BITE5 offers lighted extender probes - Midtronics does not.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

BITE5

 

Celltron Advantage

 

Picture

 

 

 

 

Cell Voltage

˜

 

˜

 

Cell Resistance

 

 

 

 

Cell Impedance

˜

 

 

 

Cell Conductance

˜

 

˜

 

Strap Resistance

 

 

˜

 

Ripple Current

˜

 

 

 

DC Float Current

˜

 

 

 

Escape Current

 

 

 

 

Temperature

˜

 

˜

 

Capacity Testing DC

Measurements

˜

 

 

 

Measures DC Voltage

1000Vdc

 

 

 

Measures AC Voltage

600Vac

 

 

 

Kelvin Clips

˜

 

˜

 

Single Tip Probes

 

 

 

 

Duplex Probes

˜

 

˜

 

Concentric Probes

˜

 

 

 

Probe Extenders

˜

 

˜

 

Display

Touchscreen

 

LCD

 

Memory

16G

 

14000 test

 

Removable Memory

˜

 

˜

 

Printer

 

 

Protocol for Printer

 

Power

 

 

7.2V, 2500mAh,

NiMH rechargable

 

Dimensions (inches)

240 x 160 x 65

 

11 x 4 x 3

 

Weight (pounds)

1.98

 

2.6

 

RS-232 Com Port

 

 

 

 

USB Port

˜

 

˜

 

Bluetooth Port

 

 

 

 

Auto Detect Cell-Strap

 

 

 

 

On Board Data Analysis

˜

 

˜

 

Accuracy

1%

 

2%

 

Max Voltage

200Vdc

 

20.0VDC

 

Test Current

100mA

 

200mA

 

Temperature Operating

Range

0 to 50C

 

0 to 40C

 

Humidity @ 40C >= 90%

85%NC

 

95%NC


 

 

Brand

Megger

 

HIOKI

 

BITE5 Advantages

The BITE5 can test battery packs up to 200Vdc - HIOKI cannot.

The BITE5 can test Lithium-Ion batteries - HIOKI cannot.

The BITE5 can measure AC Ripple current - HIOKI cannot.

The BITE5 has a large color touchscreen display - HIOKI does not.

 

The BITE5 can measure DC float current - HIOKI cannot.

 

The BITE5 can trend historical data - HIOKI cannot.

The BITE5 can measure DC voltages up to 1000V - HIOKI cannot.

 

The BITE5 supports discharge testing - HIOKI does not.

 

The BITE5 offers an optional hydrometer - HIOKI does not.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

BITE5

 

3554

 

Picture

 

 

 

 

Cell Voltage

˜

 

˜

 

Cell Resistance

 

 

 

 

Cell Impedance

˜

 

˜

 

Cell Conductance

˜

 

 

 

Strap Resistance

 

 

 

 

Ripple Current

˜

 

 

 

DC Float Current

˜

 

 

 

Escape Current

 

 

 

 

Temperature

˜

 

˜

 

Capacity Testing DC

Measurements

˜

 

 

 

Measures DC Voltage

1000Vdc

 

 

 

Measures AC Voltage

600Vac

 

 

 

Kelvin Clips

˜

 

 

 

Single Tip Probes

 

 

 

 

Duplex Probes

˜

 

˜

 

Concentric Probes

˜

 

˜

 

Probe Extenders

˜

 

 

 

Display

Touchscreen

 

LCD

 

Memory

16G

 

4800 sets

 

Removable Memory

˜

 

 

 

Printer

 

 

 

 

Power

 

 

8 AA Alkaline

Batteries

 

Dimensions (inches)

240 x 160 x 65

 

7.6 x 4.8 x 2.2

 

Weight (pounds)

1.98

 

1.75

 

RS-232 Com Port

 

 

 

 

USB Port

˜

 

˜

 

Bluetooth Port

 

 

 

 

Auto Detect Cell-Strap

 

 

 

 

On Board Data Analysis

˜

 

 

 

Accuracy

1%

 

1%

 

Max Voltage

200Vdc

 

60.0VDC

 

Test Current

100mA

 

100mA

 

Temperature Operating

Range

0 to 50C

 

0 to 40C

 

Humidity @ 40C >= 90%

85%NC

 

80%NC


 

 

Brand

Megger

 

Fluke

Fluke

 

BITE5 Advantages

The BITE5 can test battery packs up to 200Vdc - Fluke cannot.

The BITE5 can test Lithium- Ion batteries - Fluke cannot.

The BITE5 can measure AC Ripple current - Fluke cannot.

 

The BITE5 has a large color touchscreen display - Fluke does not.

 

The BITE5 can measure DC float current - Fluke cannot.

The BITE5 can trend historical data -Fluke cannot.

 

The BITE5 supports discharge testing - Fluke does not.

 

The BITE5 offers an optional hydrometer - Fluke does not.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

BITE5

 

BT-510

BT-521

 

Picture

 

 

 

 

 

Cell Voltage

˜

 

˜

˜

 

Cell Resistance

 

 

 

 

 

Cell Impedance

˜

 

˜

˜

 

Cell Conductance

˜

 

 

 

 

Strap Resistance

 

 

 

˜

 

Ripple Current

˜

 

 

˜

 

DC Float Current

˜

 

 

˜

 

Escape Current

 

 

 

 

 

Temperature

˜

 

 

˜

 

Capacity Testing DC

˜

 

 

 

Measurements

 

Measures DC Voltage

1000Vdc

 

1000Vdc

1000Vdc

 

Measures AC Voltage

600Vac

 

600Vac

600Vac

 

Kelvin Clips

˜

 

 

 

 

Single Tip Probes

 

 

 

 

 

Duplex Probes

˜

 

˜

˜

 

Concentric Probes

˜

 

˜

˜

 

Probe Extenders

˜

 

Optional

Optional

 

Display

Touchscreen

 

LCD

LCD

 

Memory

16G

 

 

 

 

Removable Memory

˜

 

 

 

 

Printer

 

 

 

 

 

Power

 

 

7.4V,3Ah,

7.4V,3Ah,

 

Rechargeable

Rechargeable

 

Lithium

Lithium

 

Dimensions (inches)

240 x 160 x 65

 

9.0 x 4.0 x 2.0

9.0 x 4.0 x 2.0

 

Weight (pounds)

1.98

 

1.9

1.9

 

RS-232 Com Port

 

 

 

 

 

USB Port

˜

 

˜

˜

 

Bluetooth Port

 

 

 

˜

 

Auto Detect Cell-Strap

 

 

 

 

 

On Board Data Analysis

˜

 

 

 

 

Accuracy

1%

 

1%

1%

 

Max Voltage

200Vdc

 

60VDC

60VDC

 

Test Current

100mA

 

100mA

100mA

 

Temperature Operating

0 to 50C

 

0 to 40C

0 to 40C

Range

 

Humidity @ 40C >= 90%

85%NC

 

80%NC

80%NC


 

 

Brand

Megger

 

Alber

 

BITE5 ADVANCED

ADVANTAGES

 

Test batteries up to 500Vdc Supports Lithium Ion Measures battery temperature

Measures ripple voltage and current

Measures DC Float Current Touchscreen

Measures DC Voltages (1000Vdc)

Ability to Retest a Cell Supports Discharge Testing On Board Data Analysis Optional Concentric Probes Optional Bluetooth

RFID reader

 

Supports logging (Z, V and Temp.)

Optional lighted extension probes

 

 

 

 

 

 

 

Model

BITE5

ADVANCED

 

CRT-400

Cellcorder

 

Picture

 

 

 

 

Cell Voltage

˜

 

˜

 

Cell Resistance

 

 

˜

 

Cell Impedance

˜

 

 

 

Cell Conductance

˜

 

 

 

Strap Resistance

˜

 

˜

 

Ripple Current

˜

 

 

 

DC Float Current

˜

 

 

 

Escape Current

˜

 

 

 

Temperature

˜

 

 

 

FRA Analysis

 

 

 

 

Capacity Testing Support

˜

 

 

 

DC Voltage Limits

˜

 

 

 

RFID Tag Support

˜

 

 

 

Logging Support

˜

 

 

 

Measures DC Voltage

1000Vdc

 

 

 

Measures AC Voltage

600Vac

 

 

 

Kelvin Clips

 

 

˜

 

Single Tip / Clip Probes

 

 

˜

 

Double Tip Probes

˜

 

 

 

Concentric Probes

˜

 

 

 

Probe Extenders

˜

 

˜

 

Display

Touchscreen

 

LCD

 

Removable Memory

˜

 

USB Stick

 

Printer

Optional

 

Optional

 

USB Port

˜

 

 

 

Bluetooth Port

˜

 

Optional Earpiece

 

IR Port

 

 

˜

 

Ability to Retest a Cell

˜

 

 

 

Auto Detect Cell-Strap

˜

 

 

 

On Board Data Analysis

˜

 

 

 

Accuracy

1.00%

 

 

 

Max Cell Voltage

500Vdc

 

20.0VDC

 

Test Current

700mA

 

35A

 

Temperature Operating Range

0 to 50C

 

0 to 40C

 

Humidity @ 40C >= 90%

85%NC

 

50%NC


 

 

Brand

Megger

 

Midtronics

 

BITE5 ADVANCED

ADVANTAGES

 

Test batteries up to 500Vdc Supports Lithium Ion Measures battery temperature

Measures ripple voltage and current

Measures DC Float Current Touchscreen

Measures DC Voltages (1000Vdc)

Supports Discharge Testing On Board Data Analysis Optional Concentric Probes Optional Hydrometer Optional Bluetooth Removeable memory

RFID reader

 

Supports logging (Z, V and Temp.)

Optional Printer Optional lighted extension

probes

 

 

 

 

 

Model

BITE5

ADVANCED

 

Celltron

Advantage

 

Picture

 

 

 

 

Cell Voltage

˜

 

˜

 

Cell Resistance

 

 

 

 

Cell Impedance

˜

 

 

 

Cell Conductance

˜

 

˜

 

Strap Resistance

˜

 

˜

 

Ripple Current

˜

 

 

 

DC Float Current

˜

 

 

 

Escape Current

˜

 

 

 

Temperature

˜

 

˜

 

FRA Analysis

 

 

˜

 

Capacity Testing Support

˜

 

 

 

DC Voltage Limits

˜

 

˜

 

RFID Tag Support

˜

 

 

 

Logging Support

˜

 

 

 

Measures DC Voltage

1000Vdc

 

 

 

Measures AC Voltage

600Vac

 

 

 

Kelvin Clips

 

 

˜

 

Single Tip / Clip Probes

 

 

 

 

Double Tip Probes

˜

 

˜

 

Concentric Probes

˜

 

 

 

Probe Extenders

˜

 

˜

 

Probe Display

 

 

 

 

Display

Touchscreen

 

LCD

 

Removable Memory

˜

 

˜

 

Printer

Optional

 

Protocol for Printer

 

USB Port

˜

 

˜

 

Bluetooth Port

˜

 

 

 

IR Port

 

 

 

 

Ability to Retest a Cell

˜

 

˜

 

Auto Detect Cell-Strap

˜

 

 

 

On Board Data Analysis

˜

 

˜

 

Accuracy

1.00%

 

2.00%

 

Max Cell Voltage

500Vdc

 

20.0VDC

 

Test Current

700mA

 

200mA

 

Temperature Operating Range

0 to 50C

 

0 to 40C

 

Humidity @ 40C >= 90%

85%NC

 

95%NC


 

 

Brand

Megger

 

HIOKI

 

BITE5 ADVANCED

ADVANTAGES

 

Test batteries up to 500Vdc

 

Supports Lithium Ion

Tests Intercell (Strap connections)

 

Measures ripple voltage and current

 

Measures DC Float Current Touchscreen

Measures DC Voltages (1000Vdc)

 

Supports Discharge Testing On Board Data Analysis Optional Concentric Probes Optional Hydrometer Optional Bluetooth Removeable memory

RFID reader

Supports logging (Z, V and Temp.)

 

Optional Printer

Optional lighted extension probes

 

Model

BITE5

ADVANCED

 

3554

 

Picture

 

 

 

 

Cell Voltage

˜

 

˜

 

Cell Resistance

 

 

 

 

Cell Impedance

˜

 

˜

 

Cell Conductance

˜

 

 

 

Strap Resistance

˜

 

 

 

Ripple Current

˜

 

 

 

DC Float Current

˜

 

 

 

Escape Current

˜

 

 

 

Temperature

˜

 

˜

 

FRA Analysis

 

 

 

 

Capacity Testing Support

˜

 

 

 

DC Voltage Limits

˜

 

˜

 

RFID Tag Support

˜

 

 

 

Logging Support

˜

 

 

 

Measures DC Voltage

1000Vdc

 

 

 

Measures AC Voltage

600Vac

 

 

 

Kelvin Clips

 

 

 

 

Single Tip / Clip Probes

 

 

 

 

Double Tip Probes

˜

 

˜

 

Concentric Probes

˜

 

˜

 

Probe Extenders

˜

 

 

 

Display

Touchscreen

 

LCD

 

Removable Memory

˜

 

 

 

Printer

Optional

 

 

 

USB Port

˜

 

˜

 

Bluetooth Port

˜

 

 

 

IR Port

 

 

 

 

Ability to Retest a Cell

˜

 

 

 

Auto Detect Cell-Strap

˜

 

 

 

On Board Data Analysis

˜

 

 

 

Accuracy

1.00%

 

1%

 

Max Cell Voltage

500Vdc

 

60.0VDC

 

Test Current

700mA

 

100mA

 

Temperature Operating Range

0 to 50C

 

0 to 40C


 

 

Brand

Megger

 

Fluke

Fluke

BITE5 ADVANCED

ADVANTAGES

 

Test batteries up to 500Vdc

 

Supports Lithium Ion

Tests Intercell (Strap connections)

 

Touchscreen Supports Discharge Testing

On Board Data Analysis Optional Concentric Probes Optional Hydrometer Removeable memory

RFID reader

Supports logging (Z, V and Temp.)

 

Optional Printer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

BITE5

ADVANCED

 

BT-510

BT-521

 

Picture

 

 

 

 

 

Cell Voltage

˜

 

˜

˜

 

Cell Resistance

 

 

 

 

 

Cell Impedance

˜

 

 

˜

 

Cell Conductance

˜

 

 

 

 

Strap Resistance

˜

 

 

˜

 

Ripple Current

˜

 

 

˜

 

DC Float Current

˜

 

 

˜

 

Escape Current

˜

 

 

 

 

Temperature

˜

 

 

˜

 

FRA Analysis

 

 

 

 

 

Capacity Testing Support

˜

 

 

 

 

DC Voltage Limits

˜

 

˜

˜

 

RFID Tag Support

˜

 

 

 

 

Logging Support

˜

 

 

˜

 

Measures DC Voltage

1000Vdc

 

 

 

 

Measures AC Voltage

600Vac

 

 

 

 

Kelvin Clips

 

 

 

 

 

Single Tip / Clip Probes

 

 

 

 

 

Double Tip Probes

˜

 

˜

˜

 

Concentric Probes

˜

 

˜

˜

 

Probe Extenders

˜

 

˜

˜

 

Display

Touchscreen

 

LCD

LCD

 

Removable Memory

˜

 

 

 

 

Printer

Optional

 

 

 

 

USB Port

˜

 

˜

˜

 

Bluetooth Port

˜

 

 

˜

 

IR Port

 

 

 

 

 

Ability to Retest a Cell

˜

 

˜

˜

 

Auto Detect Cell-Strap

˜

 

 

 

 

On Board Data Analysis

˜

 

 

 

 

Accuracy

1.00%

 

1%

1%

 

Max Cell Voltage

500Vdc

 

60VDC

60VDC

 

Test Current

700mA

 

100mA

100mA

 

Temperature Operating

Range

0 to 50C

 

0 to 40C

0 to 40C

 


Can’t find what you’re looking for?